Skip to main content

RequestUpdateMasterDataMeteringPoint

RequestUpdateMasterDataMeteringPoint

Header

Ref. Header

Process

Ref. Process

Payload


PointCharacteristics class Element
Attribute

Lv

Definition

Description

Card

Max
Length

Content

XML element

MasterData Metering
Point Event

1

MasterData Metering Point Event Class

Repeating payload is only allowed for BRS-NO-317, Update estimated annual consumption.

1..9999



PayloadMasterDataMPEvent

Start of occurrence

2

The valid start date and time for the MasterData changes.

For additional information, ref. DateTime elements

0..1


YYYY-MM-DDTHH:MM:SSZ
or
YYYY-MM-DDTHH:MM:SS[+-][HH:MM]

StartOfOccurrence

Identification2Identification of the individual payload. Valid for BRS-NO-317 only. 0..1A36UUIDIdentification

Original Business Document Reference

2

The identification of the original RequestUpdateMasterDataMeteringPoint message used in case of a rollback.


0..1

A36

UUID 

 OriginalBusinessDocumentReference

Metering Point

2

Identification of the metering point


1..1



MeteringPointUsedDomainLocation

Identification

3

Unique identification of the metering point.

Global Service Relationship Number (GSRN) from GS1 is used for identification of metering points.

1..1

A18


Identification

schemeAgencyIdentifier

3

Attribute to the identification of the metering point

Identification of the agency maintaining the metering point identification.

9 GS1

1..1

A1

9

schemeAgencyIdentifier

Metering Grid Area

2

Identification of the metering grid area the Metering Point is connected to


0..1



MeteringGridAreaUsedDomainLocation

Identification

3

Unique identification of the metering grid area.

EIC-Y code from ENTSO-E is used for identification of metering grid areas.

1..1

A16


Identification

schemeAgencyIdentifier

3

Attribute to the identification of the metering grid area

Identification of the agency maintaining the metering grid area identification.

305 EIC 

1..1

A3

305

schemeAgencyIdentifier

Metering Point Address

2

Specification of the address of the Metering Point


0..1



MPAddressMeteringPointAddress

Street name

3

Name of street


0..1

A150


StreetName

Street code

3

This may be set to the code identifying a street within a municipality (according to the reference provided by the Norwegian Mapping Authority).

Mainly included for compatibility with ebIX.

0..1

A10


StreetCode

Building number

3

Building number in street


0..1

A10


BuildingNumber

Floor identification

3

Floor identification in building


0..1

A10


FloorIdentification

Room identification

3

Room identification in building


0..1

A10


RoomIdentification

Post code

3

Post code linked to the city name


1..1

A10


Postcode

City name

3

Name of city


1..1

A50


CityName

City sub division name

3

A sub-division of the city name. Not used for addresses in Norway, although the location exists.

Mainly included for compatibility with ebIX.

0..1

A50


CitySubDivisionName

Municipality code

3

Code to identify the municipality the address belongs to

The Norwegian municipality code follows a string[4] format specification and has currently values from 0101 to 2030.

0..1

A10


MunicipalityCode

Country

3

Country code

The country code according to ISO 3166-1 alpha-2.

1..1

A2


CountryCode

listAgencyIdentifier

3

Attribute to the country code

Identification of the agency maintaining the codelist used for country codes .
5 ISO

1..1

A1


listAgencyIdentifier

FreeForm

3

A free form representation of this address, expressed as text


0..1

A100


AddressFreeForm

Metering Point Geographical Coordinate

2

Geographical coordinates of the Meter connected to the Metering Point

WGS84 scheme should be used for GPS coordinates.

0..1



MPPositionMeteringPointGeographicalCoordinate

Latitude

3

The latitude part of the coordinate


1..1

Decimal (8.5)


Latitude

Longitude

3

The longitude part of the coordinate


1..1

Decimal (8.5)


Longitude

Metering Point Address Cadastral

2

The address cadastral

In Norwegian this is Gårdsnr (Gnr), Bruksnr (Bnr), Seksjonsnr (Snr), Festenr (Fnr)

0..1



MPAddressCadastral

Gårdsnummer

3

Specific location parameter as governed (in Norway) by the Norwegian Mapping Authority.


1..1

A10


Gnr

Bruksnummer

3

Specific location parameter as governed (in Norway) by the Norwegian Mapping Authority.


1..1

A10


Bnr

Seksjonsnummer

3

Specific location parameter as governed (in Norway) by the Norwegian Mapping Authority.


0..1

A10


Snr

Festenummer

3

Specific location parameter as governed (in Norway) by the Norwegian Mapping Authority.


0..1

A10


Fnr

Metering Point Characteristics

2

Metering point characteristics


0..1



MpDetailMeteringPointCharacteristic

Metering Point type

3

A code specifying the direction of the active energy flow in this Metering Point, such as consumption, production.

Codes according to ebIX.
Ref. Metering Point Type

0..1

A3


MeteringPointType

listAgencyIdentifier

3

Attribute to the metering point type

Identification of the agency maintaining metering point types.

260 ebIX

1..1

A3

260

listAgencyIdentifier

Metering point subtype consumption

3

A code specifying the type of consumption for consumption metering points.

Valid codes: Ref. Subtype Consumption
Note that on metering points of type Combined, both metering point subtype consumption and metering point subtype production is used.

0..1

A3


MeteringPointSubTypeConsumption

listAgencyIdentifier

3

Attribute to the metering point subtype consumption element

Identification of the agency maintaining metering point subtype consumption codes

89 Elhub

1..1

A2

89

listAgencyIdentifier

Metering point subtype production3A code specifying the type of production for production metering points.Valid codes: Ref. Subtype Production0..1A3
MeteringPointSubTypeProduction

listAgencyIdentifier

3

Attribute to the metering point subtype production element

Identification of the agency maintaining metering point subtype production codes

89 Elhub

1..1

A2

89

listAgencyIdentifier

Meter Reading Characteristics

3

A code specifying how the Metered Data Collector collects data from the Meter for this Metering Point, such as Automatic or Manually.

Valid codes:
Ref. Meter Reading Characteristics

0..1

A3


MeterReadingCharacteristics

listAgencyIdentifier

3

Attribute to the meter reading characteristics

Identification of the agency maintaining meter reading characteristics codes.

260 ebIX

1..1

A3

260

listAgencyIdentifier

Settlement Method

3

A code specifying how the energy volumes are treated for settlement for this Metering Point, such as profiled or non-profiled

Ref. Settlement Method Type

0..1

A3


SettlementMethodType

listAgencyIdentifier

3

Attribute to the settlement method

Identification of the agency maintaining settlement methods

89 Elhub
260 ebIX

1..1

A3


listAgencyIdentifier

Physical Status of Metering Point

3

A code specifying if the installation of the Metering Point is physically connected to the grid

Codes according to ebIX.
Ref. Physical Status Type

0..1

A3


PhysicalStatusType

listAgencyIdentifier

3

Attribute to the physical status type

Identification of the agency maintaining physical statuses

260 ebIX

1..1

A3

260

listAgencyIdentifier

Load limit

3

Load limit on the metering point

The maximum load in kW in a consumption metering point a specific point in time. If stored as Ampere in the source system this must be converted to effect.

0..1

I9


ContractedConnectionCapacityValue

Installed capacity

3

Installed capacity for production metering points

Installed capacityor maximum effect, is the intended full-load sustained output of a facility such as a power plant.

0..1

I9


InstalledCapacity

Meter reading start date

3

Start date and time of meter reading

Use together with meter reading frequency (ref. below) to calculate next planned meter reading

0..1

dateTime


MeterReadingStartDate

Meter reading frequency

3

The expected reading interval for a manually read meter in number of readings per year


0..1

I4


MeterReadingFrequencyDuration

Description

3

For consumption metering points: Free text description of the metering point. Optional.
For production and combined metering points: Name of production unit. Required.


0..1

A80


Description

Priority

3

Code to indicate if the metering point is interruptible or not

Valid codes: Ref. Priority codes

0..1

A1


Priority

Blocked for switching3Indicator to block the metering point for switching of balance supplierTrue if the metering point is blocked for switching 0..1
true/falseBlockedForSwitching
Meter Reading Occurance3See EIM Målepunkt
0..1
PT15M/PT1H/PT5M/PT60MMeterReadingOccurrence

Estimated annual consumption

2

kWh for consumption. Updated for profiled metering points


0..1



AnnualPeriodEstimatedMetrics

Total

3

Expected consumption value


1..1

I12


Total

Calculation method3Code to indicate how the EAC is calculatedValid codes. Ref. Calculation Method1..1A9
CalculationMethod

Meter information

2

Information regarding the meter connected to the Metering Point


0..1



MeteringInstallationMeterFacility

Meter Identification

3

Identification number of the meter at the metering point


1..1

A18


MeterIdentification

Number of digits

3

Number of significant digits on a profiled/manually read meter


0..1

I2


NumberOfDigits

Meter constant

3

Value to convert the register read to actual consumption/production


0..1

Decimal
(12.5)


Constant

Meter location

3

Description of the meter location


0..1

A80


MeterLocation

Taxation Profile

2

Information regarding various tax elements on the metering point


0..1



MPTaxationProfile

VAT Code

3

Code to indicate the Value Added Tax percentage.

Valid codes: Ref. Vat Code

0..1

A1


VATCode

Enova fee type

3

Type of the Enova fee: Fixed or dependent on consumption

Valid codes:
Fixed
ConsumptionDependent

0..1

A20

Fixed or
Consumption
Dependent

EnovaFeeType

Enova fee share

3

The share of the volume which will be used for the Enova fee calculations (in percentage points)


0..1

Decimal
(5.2)


EnovaFee

El fee share

3

The share of the volume which will be used for the El fee calculations (in percentage points)


0..1

Decimal
(5.2)


ElFee

El certificate share

3

The share of the volume which will be used for El-certificate calculations (in percentage points)


0..1

Decimal
(5.2)


ElCertificateShare

ConsumptionCode3Code describing the consumption in the metering pointRef. Consumption Code0..1A10
ConsumptionCode

NACE DivisionCode

3

The DivisionCode ("Næringskode") of the customer.

Valid codes. Ref. NACE Division Codes (Næringskode)

0..1

A10


NACE_DivisionCode

Measurement Definition2Specification of the characteristics of the metering taking place on the metering point.
0..99

MeasurementDefinition

Product Included Product Characteristics

3

Product Included Product Characteristics Complex Type


1..1



ProductIncludedProductCharacteristics

Product

4

Identification of an energy product such as power, energy, reactive power, transport capacity, etc.

This identifies the product for which the time series is reporting. 
Valid codes. Ref. Product identifier

1..1

A13


Identification

schemeAgencyIdentifier

4

Attribute to the Product

Identification of the agency issuing the identifiers used for energy products 

9  GS1

1..1

A1

9

schemeAgencyIdentifier

Unit type

4

The unit of measure that is applied to the quantities in which the metering values are expressed.

Valid codes: Ref. Unit Type

1..1

A5


UnitType

Direction3

A code specifying the direction of the energy flow.

Valid codes:
In
 - Production 
Out - Consumption

1..1A3In/OutDirection
Resolution3Code for the resolution of the metering values

Resolution

1..1A5PT60M/PT1H/
PT15M/N
Resolution
JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.