15 - Update of masterdata - from Grid Access Provider
Update of masterdata – from Grid Access Provider
This process is used to update master data for a metering point. The process starts with the message RequestUpdateMasterDataMeteringPoint from the grid access provider to Elhub. If the content of the message violates the validation rules, the Acknowledgement message with Status 41 - Rejected is returned.
Sequence diagram update of masterdata – from grid access provider
Messages update of masterdata – from grid access provider
The messages used in the process are described below.
RequestUpdateMasterDataMeteringPoint
Code usage
Element name | Code | Code list | Description |
---|---|---|---|
Document Type | E58 | ebIX | Request to change metering point attributes |
E67 | ebIX | Cancellation | |
Business Process | BRS-NO-121 | Elhub | New metering point |
BRS-NO-122 | Elhub | Activation of metering point | |
BRS-NO-132 | Elhub | Rollback of activation of metering point | |
BRS-NO-212 | Elhub | Deactivation of metering point | |
BRS-NO-214 | Elhub | Deactivation of metering point with end user | |
BRS-NO-213 | Elhub | Removal of metering point | |
BRS-NO-223 | Elhub | Rollback of deactivation of metering point | |
BRS-NO-224 | Elhub | Rollback of removal of metering point | |
BRS-NO-302 | Elhub | Update of master data - grid owner | |
BRS-NO-306 | Elhub | Settlement type change | |
BRS-NO-317 | Elhub | Update of estimated annual consumption | |
BRS-NO-402 | Elhub | Corrections of master data - from grid owner | |
Business Process Role | DDM | UN/CEFACT | Grid access provider |
Message Implementation Guide
Ref. RequestUpdateMasterDataMeteringPoint