SYS-DDQ111-03 Rollback - start of supply - move in - back in time more than 30 working days
Test ID | SYS-DDQ111-03 |
BRS's | BRS-NO-103 BRS-NO-111 |
Roles | DDQ |
Preconditions | Metering point should have metering point status E22 (active) in Elhub |
Postconditions | The initiating balance supplier does not have active contract on the metering point |
Optional/Mandatory | Mandatory |
Test steps | Expected Result |
1. Send BRS-NO-103 to Elhub
| Request is successfully sent |
2. Receive RejectStartOfSupply to DDQ (optional)
| RejectStartOfSupply is received to DDQ |
3. Send BRS-NO-111 til Elhub
| Request is successfully sent |
4. Receive ConfirmStartOfSupply to DDQ (optional)
| ConfirmStartOfSupply is received to DDQ |