SYS-DDM211-03 Correction of move out date from Grid Access Provider
Test ID | SYS-DDM211-03 |
Description | Correction of move out date from Grid Access Provider |
BRS's | BRS-NO-211 |
Roles | DDM |
Preconditions | Metering point should have metering point status E22 (active) in Elhub Metering point should have active contract with Grid Access Provider |
Postconditions | The end date of the Grid Access contract has been updated in accordance to correction date |
Optional/Mandatory | Mandatory |
Test steps | Expected Result |
| Request is successfully sent |
2. Receive ConfirmEndOfSupply to DDM (optional)
| ConfirmEndOfSupply is received to DDM |
3. Send BRS-NO-211 with correction to Elhub after cancellation deadline
| Request is successfully sent |
4. Receive ConfirmEndOfSupply to DDM (optional)
| ConfirmEndOfSupply is received to DDM |
5. Verify that DDM's system is updated correctly | The BRS-NO-211 is corrected and the end date of the Grid Access contract has been updated in accordance to correction date |