SYS-DDM123-02 Create, activate and move in on a profiled metering point Test IDSYS-DDM123-02DescriptionCreate, activate and move in on a profiled, consumption metering pointBRS'sBRS-NO-121BRS-NO-122BRS-NO-123RolesDDMPreconditionsMetering point must not exist in Elhub PostconditionsA profiled, comsumption metering point must be created and activatedMetering points must have active contract with Supplier of last resortOptional/MandatoryMandatoryTest stepsExpected ResultSend BRS-NO-121 til ElhubMessage: RequestUpdateMasterDataMeteringPointDocument type: E58Request is successfully sent 2. Receive positive acknowledgement to DDM (optional)Document type: 294Positive Acknowledgement is received to DDM3. Send BRS-NO-122 to ElhubMessage: RequestUpdateMasterDataMeteringPointDocument type: E58Request is successfully sent4. Receive positive acknowledgement to DDM (optional)Document type: 294Positive Acknowledgement is received to DDM5. Send BRS-NO-123 to ElhubMessage: RequestStartOfSupplyDocument type: 392Request is successfully sent6. Receive ConfirmStartOfSupply to DDM (optional)Document type: 414ConfirmStartOfSupply is received to DDM7. Receive NotifyStartOfSupply to DDMDocument type: 414NotifyStartOfSupply is received by DDM8. Verify that DDM's system is updated correctlyMetering pont is created and activated and has an active contract withSupplier of last resort ×