SYS-AG313-02 Receive metering values for non-profiled metering point
SYS-AG313-02 Receive metering values for non-profiled metering point
Test ID
SYS-AG313-02
Description
Receive metering values for non-profiled metering point
BRS's
BRS-NO-622
BRS-NO-313
Roles
AG
DDE
Preconditions
The metering point must be non-profiled
The metering point must have a balance supply contract with an end user
Postconditions
The requested metering values have been received from Elhub and are visible in DDQ's system. Message contains timestamps for registration date time and insert time
Optional/Mandatory
Mandatory
Test steps
Expected Result
1. Send BRS-NO-622 to Elhub
Request is successfully sent
2. Receive Acknowledgement
Document type: 294
Positive Acknowledgement is received to AG
3. End user accepts the access request. This is done manually by Elhub and could take a couple of days
Access request for the metering point is accepted by the end user
4. Ediel portal operates as DDE and sends meter values for the metering point to Elhub
Metering values are sent by Ediel to Elhub
5. Receive BRS-NO-313 to AG
BRS-NO-313 is received to AG
6. Verify that AG's system is updated correctly
Meter reads are stored and are visible for AG