SYS-AG303-01 Request master data
Test ID | SYS-AG303-01 |
Description | Request master data |
BRS's | BRS-NO-303 BRS-NO-622 |
Roles | AG |
Preconditions | AG must have a valid contract with end user to access information The metering point must have a balance supply contract with an end user |
Postconditions | |
Optional/Mandatory | Mandatory |
Test steps | Expected Result |
1. Send BRS-NO-622
| Request is successfully sent |
2. Receive Acknowledgement (optional)
| Positive Acknowledgement is received to AG |
3. Send BRS-NO-303 on the same metering point
| Request is successfully sent |
4. Receive NotifyMeteringPointCharacteristics
| NotifyMeteringPointCharacteristics is received to AG |