SYS-DDQ102-04 Test IDSYS-DDQ102-04DescriptionSend a move in on an inactive metering pointBRS'sBRS-NO-102RolesDDQ, DDMPreconditionsMetering point should be consumption, non profiled and have metering point status 'Inactive' in ElhubPostconditionsThe metering point status is still 'Inactive' in Elhub and no new balance supply contract is created for the metering point in DDQ's systemOptional/MandatoryMandatoryTest stepsExpected ResultDDQ sends BRS-NO-102 to ElhubMessage: RequestStartOfSupplyDocument type: 392Message is successfully sent2. Receive ConfirmStartOfSupply to DDQ (optional)Document type: 414ConfirmStartOfSupply is received to DDQ3. DDM sends RejectStartOfSupply with error code "EH095 - Metering point cannot be activated" to ElhubThe Ediel portal is operating as Grid Access Provider (DDM)RejectStartOfSupply is sent to Elhub by DDM4. DDQ receive RejectStartOfSupply with error code "EH095 - Metering point cannot be activatedRejectStartOfSupply is received to DDQ5. Verify that DDQ's system is updated correctlyMetering point is still inactive in Elhub and no new balance supply contract is created for the metering point ×