SYS-DDM311-01 Receive information about Estimated annual consumption Test IDSYS-DDM311-01DescriptionReceive information about Estimated annual consumption (EAC) from Balance supplierBRS'sBRS-NO-311RolesDDM, DDQPreconditionsMetering points must be profiledMetering points must have active contract with new Balance supplierDDM must have grid access contract in MGAPostconditionsProposed new EAC is receivedOptional/MandatoryMandatoryTest stepsExpected ResultDDQ sends BRS-NO-103 to ElhubThe Ediel portal is operating as Balance supplierRequest is successfully sent from Ediel portal to Elhub2. DDQ sends BRS-NO-311 to ElhubThe Ediel portal is operating as Balance supplierRequest is successfully sent from Ediel portal to Elhub3. DDM receives CollectedData with proposed EACDocument type: 294CollectedData is successfully received by DDM ×