This process is used as a reminder to a Metered Data Responsible to request missing metering values and as a reminder for outdated estimated annual consumption (EAC) to a Grid Access Provider. The process starts with the message RequestCollected Data from Elhub to a Metered Data Responsible / Grid Access Provider. If the Metered Data Responsible have metering values available in the requested observation period, the metering values are returned to Elhub in the next scheduled transmission of the message CollectedData which normally is at least once a day.  If the Grid Access Provider has an updated estimated annual consumption (EAC) available, the EAC is sent to Elhub by using the RequestUpdateMasterDataMeteringPoint message  

Sequence diagram reminder to metered data responsible

 

Message reminder to metered data responsible

The message used in the process is described below.

Request Collected Data

Code usage

Element name

Code

Code list
responsible

Description

Document Type

E39

ebIX

Request meter readings

Business Process

BRS-NO-314

Elhub

Reminder for metering values

Business Process Role

MDR

UN/CEFACT

Metered Data Responsible


DDM

UN/CEFACT

Grid Access Provider


Message Implementation Guide
Ref. RequestCollectData