Skip to main content

UpdateMeteringPointCollection

Header

Ref. Header

Process

Ref. Process

Attribute

Lv

Definition

Description

Card

Max Length

Content

XML Element

Start Of Occurrence

2

The valid start date and time for the metering point collection.

For additional information, ref. DateTime elements.

Must be midnight aligned

0..1

YYYY-MM-DDTHH:MM:SSZ
or
YYYY-MM-DDTHH:MM:SS[+-][HH:MM]

StartOfOccurrence

Update Indicator

2

Indicator for Add, Delete or Update of metering point

Add A new collection of metering points are created
Delete An existing collection of metering points are deactivated
Update An existing collection of metering points are updated. The grid owner can for example add new metering points, update the shares or change the formula type of an existing collection.

1...1

A6

Add/Delete/Update

UpdateIndicator

Metering Point Collection

2

Information about the collection of metering points

1...1

MeteringPointCollection

Version

3

Shows which version of the collection we are on. 

After each update a new version will be created. This attribute shows what is the current version of the metering point collection

0...1

Name

3

The name of the collection of metering points 

0...1

Description

3

Description of the collection of metering points

0...1

CollectionID

3

The unique ID for the collection of metering points

0...1

A36

UUID

Identification

TemplateType

3

Which template is being used for the calculations of virtual metering points

SharedProduction is currently the only supported TemplateType

0...1

A16

SharedProductionTemplateType

FormulaType

3

Determines the formula for which the production will be shared between the participants

ByConstants The participants in the collection get their share of the production. the shares each participant gets has to be set manually by the grid owner

Equal The production is split equally between all the participants

ByConsumption The production is spread between the participants based on the amount of consumption they have.

0...1

A13

FormulaType

Settlement Status

3

Determines if the contributors and participants of the collection will end up settled or not settled

For additional information, Ref: Settlement Method Type

0...1

SettlementStatus

Collection Status

3

Determines the status of the collection

The collection can be active (E22) or inactive (E23). Ref: Physical Status Type

0...1

CollectionStatus

Collection Participants

3

Determines the role and share of all the metering points that are participating in the metering point collection

0...1000

MeteringPointCollectionParticipantType

CollectionRole

4

Determines the role the metering point has in the collection

Participant This is used for the consumption points that will receive the production

Contributor This is used for the production or combined metering points that will be sharing the production

1...1

A11

Role

CollectionShare

4

The participant's share of the production is determined by dividing the production in the collection based on the manual share per metering point.

Has to be a number between 0 and 1. All the shares for all the participants have to add up to 1

0....1

Desimal, 6 sifrer etter koma

Share

Metering Point

4

An entity where energy products are metered or calculated

Identification of the metering point

1..1

MeteringPointUsedDomainLocation

Identification

5

Unique identification of the metering point.

Global Service Relationship Number (GSRN) from GS1 is used for identification of metering points.

1..1

A18

Identification

JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.