Skip to main content

CollectedData

CollectedData


Header

Ref. Header

Process

Ref. Process

Payload


Element
Attribute

Lv

Definition

Description

Card

Max
Length

Content

XML element

Energy Time Series

1

Time Series Class which also may contain meter reads and estimated annual consumption


1..
9999



PayloadEnergyTimeSeries

Identification

2

Unique identification of the time series / meter reads.


1..1

A36

UUID

Identification

Registration date and time

2

The date and time of the registration of this set of collected data.

For additional information, ref. DateTime elements

1..1


YYYY-MM-DDTHH:MM:SSZ
or
YYYY-MM-DDTHH:MM:SS[+-][HH:MM]

RegistrationDateTime

Observation Period

2

A specific period of time describing the duration of this set of collected data.


0..1



ObservationPeriodTimeSeriesPeriod

Resolution

3

The resolution of this set of collected data expressed as a duration between the start and end of subsequent observations within this set of collected data.

The resolution is expressed a code. Ref. Resolution Duration

Mandatory for time series. Not applicable for meter reads.

0..1

A5


ResolutionDuration

Start date/time

3

Start date/time of the observation period

For additional information, ref. DateTime elements

This element is also used for meter index (date and time of the meter index read) and estimated annual consumption (date and time from when the EAC is valid) in BRS-NO-311.

0..1


YYYY-MM-DDTHH:MM:SSZ
or
YYYY-MM-DDTHH:MM:SS[+-][HH:MM]

Start

Meter reading on start date/time

3

Meter reading on the start date/time

Used for period volumes and start indexes

0..1

Decimal(15.3)


MeterReadingStart

End date/time

3

End date/time of the observation period

For additional information, ref. DateTime elements

0..1


YYYY-MM-DDTHH:MM:SSZ
or
YYYY-MM-DDTHH:MM:SS[+-][HH:MM]

End

Meter reading on end date/time

3

Meter reading on the end date/time

Used for period volumes

0..1

Decimal(15.3)


MeterReadingEnd

Product Included Product Characteristics

2

Product Included Product Characteristics Complex Type


0..1



ProductIncludedProductCharacteristics

Product

3

Identification of an energy product such as power, energy, reactive power, transport capacity, etc.

This identifies the product for which the time series is reporting.
Valid codes. Ref. Product identifier

1..1

A13


Identification

schemeAgencyIdentifier

3

Attribute to the Product

Identification of the agency issuing the identifiers used for energy products

9 GS1

1..1

A1

9

schemeAgencyIdentifier

Unit type

3

The unit of measure that is applied to the quantities in which the time series is expressed.

Valid codes: Ref. Unit Type

1..1

A5


UnitType

Metering characteristics

2

Specification of metering characteristics


0..1



MPDetailMeasurementMeteringPointCharacteristic

Direction

3

A code specifying the direction of the energy flow.

In - Production 
Out - Consumption

1..1

A3


Direction

Metering Point

2

An entity where energy products are metered or calculated

Identification of the metering point

1..1



MeteringPointUsedDomainLocation

Identification

3

Unique identification of the metering point.

Global Service Relationship Number (GSRN) from GS1 is used for identification of metering points.

1..1

A18


Identification

schemeAgencyIdentifier

3

Attribute to the identification of the metering point

Identification of the agency maintaining the metering point identification.

9 GS1

1..1

A1

9

schemeAgencyIdentifier

Observation

2

Observation class for interval values

This class is only used for continuous time series and is mutually exclusive with the ProfiledObservation and AnnualPeriodEstimatedMetrics classes below (xsd:choice).

0.. 
9999



Observation

Sequence

2

The ordinal position of this observation in this set of collected data.


1..1

I4


Sequence

Metered

3

The value as read from the register for this observation. (quality code = 127)

Only one of the quantities Metered, Estmated and Temporary is used per observation 
(xsd:choice) 

0..1

Decimal(15.3)


Metered

Estimated3Estimated quantityQuantity estimated according to the VEE guide with quality code 56 or 81.0..1Decimal(15.3)
Estimated
Quality3The quality of the quantity

56 Estimated
81 Final estimate

1..1A2
Quality

Validation code

3

Type of validation used when validating the meter reading

Valid codes: Ref. Validation code

1..1

A4


ValidationCode

Estimation code

3

Estimation method used when estimating meter reading

Valid codes: Ref. Estimation code

1..1

A4


EstimationCode

Temporary3Quantity regarded as temporary (quality code = 21)
0..1Decimal(15.3)
Temporary

Validation code

3

Type of validation used when validating the meter reading

Valid codes: Ref. Validation code

1..1

A4


ValidationCode

Estimation code

3

Estimation method used when estimating the temporary meter reading

Valid codes: Ref. Estimation code

0..1

A4


EstimationCode

Profiled Observation 2

Observation class for period volumes and indexes

This class is only used for period volumes and indexes, and is mutually exclusive with the Observation class above and AnnualPeriodEstimatedMetrics below (xsd:choice)

0..1



ProfiledObservation

Metered3The volume for this observation. (quality code = 127). May be negative.Only one of the elements Metered, Stipulated, Withdrawn and MeterIndex is used per observation 
(xsd:choice) 
0..1Decimal(15.3)
Metered

Reason for meter reading

3

The reason for this meter reading.

Valid codes. Ref. Meter read reason code

1..1

A1


MeterReadReasonCode

Stipulated3Stipulated volume. May be negative.Quantity stipulated by the metered data collector0..1Decimal(15.3)
Stipulated

Reason for meter reading

3

The reason for this meter reading.

Valid codes. Ref. Meter read reason code

1..1

A1


MeterReadReasonCode

Withdrawn3Withdrawn indicator (quality code = 58)Must be set to true to indicate that a volume is to be withdrawn0..1booleantrueWithdrawn
MeterIndex3The value as read from the register for this observation. (quality code = 127)Only applicable for meter index from balance suppliers0..1Decimal(15.3)
MeterIndex

Reason for meter reading

3

The reason for this meter reading.

Valid codes. Ref. Meter read reason code

1..1

A1


MeterReadReasonCode

Estimated annual consumption

2

kWh for estimated annual consumption. Updated for profiled metering points

This class is only used estimated annual consumption and is mutually exclusive with the Observation class and ProfiledObservation class above (xsd:choice).

0..1



AnnualPeriodEstimatedMetrics

Total

3

Estimated consumption value.


1..1

I12


Total