Skip to main content

22 - End in metering point - from Grid Access Provider

End in metering point – from Grid Access Provider

This process is generally used for deactivation of a metering point due to customer move out in case the customer is informing the grid access provider directly of the move out instead of the balance supplier.
The following business processes are supported:

  • Customer move out
  • Cancellation/rollback of customer move out

The process starts with the message Request end of supply from the grid access provider to Elhub. If the validation of the message is OK and the element regarding positive acknowledgement is set in the Header class, the message ConfirmEndOfSupply is returned.  If the message violates the validation rules the message RejectEndOfSupply is returned.

Sequence diagram end in metering point – from grid access provider

 

Messages end in metering point – from grid access provider

The messages used in the process are described below.

Request End of Supply

Code usage

Element name

Code

Code list
responsible

Description

Document Type

432

UN/CEFACT

Notification of contract termination


E02

ebIX

Cancellation of supply

Business Process

BRS-NO-211

Elhub

Move out from metering point - from grid owner


BRS-NO-222ElhubRollback of move out

Business Process Role

DDM

UN/CEFACT

Grid access provider


Message Implementation Guide
Ref. RequestEndOfSupply

Confirm end of supply

Code usage

Element name

Code

Code list
responsible

Description

Document Type

406

UN/CEFACT

Notification to supplier of contract termination


E02

ebIX

Cancellation of supply

Business Process

BRS-NO-211

Elhub

Move out from metering point - from grid owner


BRS-NO-222ElhubRollback of move out

Business Process Role

DDM

UN/CEFACT

Grid access provider

Message Implementation Guide 

Ref. ConfirmEndOfSupply

Reject end of supply


Code usage

Element name

Code

Code list
responsible

Description

Document Type

406

UN/CEFACT

Notification to supplier of contract termination


E02

ebIX

Cancellation of supply

Business Process

BRS-NO-211

Elhub

Move out from metering point - from grid owner


BRS-NO-222ElhubRollback of move out

Business Process Role

DDM

UN/CEFACT

Grid access provider

ResponseReason

E10

ebIX

Metering point not identifiable


E16

ebIX

Unauthorized balance supplier


E17

ebIX

Requested switch date not within time limits


E22

ebIX

Metering point blocked for switching

Message Implementation Guide
Ref. RejectEndOfSupply



JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.